Review




Structured Review

Millar Inc pvan ultra 1.1 data analysis software
Pvan Ultra 1.1 Data Analysis Software, supplied by Millar Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/pvan/pvan+ultra+1+1+data+analysis+software/pm40358169-117-4-10
Average 90 stars, based on 1 article reviews
pvan ultra 1.1 data analysis software - by Bioz Stars, 2026-09
90/100 stars

Images

Related Articles

Staining:

Article Title: Olaparib protects cardiomyocytes against oxidative stress and improves graft contractility during the early phase after heart transplantation in rats
Article Snippet: With the use of a special pressure‐volume analysis programme (PVAN, Millar Instruments, Houston, TX, USA), heart rate, systolic and diastolic blood pressures, mean arterial pressure, LV end‐systolic pressure, LV end‐diastolic pressure, effective arterial elastance (Ea), maximal slope of systolic pressure increment (dP/dt max ) and diastolic pressure decrement (dP/dt min ), and time constant of the left ventricular pressure decay (Tau‐g; according to the Glantz method (Pacher et al., 2008 )) were calculated.

Article Title: Cinaciguat prevents the development of pathologic hypertrophy in a rat model of left ventricular pressure overload
Article Snippet: LV end-systolic pressure and volume (LVESP and LVESV), LV end-diastolic pressure and volume (LVEDP and LVEDV), the maximum (dP/dtmax) rate of LV pressure change, time constant of LV pressure decay [τ; according to the Glantz method], EF and stroke work (SW) were computed and calculated using a special P-V analysis program (PVAN, Millar Instruments).

Article Title: Therapeutic effects on the development of heart failure with preserved ejection fraction by the sodium-glucose cotransporter 2 inhibitor dapagliflozin in type 2 diabetes
Article Snippet: A commercially available programme (PVAN, Millar Instruments, Houston, USA) was used to calculate mean arterial pressure (MAP), ejection fraction (EF), cardiac output (CO), the maximal slope of systolic pressure increment (dP/dt max ), and diastolic pressure decrement (dP/dt min ), and time constant of LV pressure decay (Tau w ).

Article Title: Targeted P2X 7 R shRNA delivery attenuates sympathetic nerve sprouting and ameliorates cardiac dysfunction in rats with myocardial infarction.
Article Snippet: Background: Inflammation-dominated sympathetic sprouting adjacent to the necrotic region following myocardial infarction (MI) has been implicated in the etiology of arrhythmias resulting in sudden cardiac death; however, the mechanisms responsible remain to be elucidated.. Although P2X7R is a key immune mediator, its role has yet to be explored.. Objective: We investigated whether P2X7R regulates NF-κB and affects cardiac sympathetic reinnervation in rats undergoing MI.

Article Title: Cardiac effects of acute exhaustive exercise in a rat model.
Article Snippet: Briefly, with the use of a special P-V analysis program (PVAN, Millar Instruments), heart rate (HR), LV end-systolic pressure (LVESP), LV end-diastolic pressure (LVEDP), the maximal slope of LV systolic pressure increment (dP/dtmax) and diastolic pressure decrement (dP/dtmin), time constant of LV pressure decay [τ; according to the Weiss method and Glantz method], LV end-systolic volume (LVESV), LV end-diastolic volume (LVEDV), stroke volume (SV), cardiac output (CO), ejection fraction (EF) and stroke work (SW) were computed and calculated.

Article Title: Inhibition of Notch signaling pathway attenuates sympathetic hyperinnervation together with the augmentation of M2 macrophages in rats post-myocardial infarction.
Article Snippet: A 2-Fr microtip P-V catheter (SPR-869; Millar Instruments, Houston, TX) was inserted into the right carotid artery and advanced into the ascending aorta to measure left ventricular (LV) systolic and diastolic pressure as the mean of measurements of five consecutive pressure cycles with the use of a special P-V analysis program (PVAN, Millar Instruments) (18, 36).

Article Title: A comparison of passive hindlimb cycling and active upper-limb exercise provides new insights into systolic dysfunction after spinal cord injury.
Article Snippet: Using specialized PV analysis software (PVAN, 199 Millar Instruments) the following systolic indices were measured from the final 30s of baseline data; end-200 systolic pressure (Pes); the maximal rate of rise of the LV pressure waveform (dP/dtmax); stroke work 201 (SW; area inside the PV loop); CO; and SV.

Western Blot:

Article Title: Olaparib protects cardiomyocytes against oxidative stress and improves graft contractility during the early phase after heart transplantation in rats
Article Snippet: With the use of a special pressure‐volume analysis programme (PVAN, Millar Instruments, Houston, TX, USA), heart rate, systolic and diastolic blood pressures, mean arterial pressure, LV end‐systolic pressure, LV end‐diastolic pressure, effective arterial elastance (Ea), maximal slope of systolic pressure increment (dP/dt max ) and diastolic pressure decrement (dP/dt min ), and time constant of the left ventricular pressure decay (Tau‐g; according to the Glantz method (Pacher et al., 2008 )) were calculated.

Article Title: Cinaciguat prevents the development of pathologic hypertrophy in a rat model of left ventricular pressure overload
Article Snippet: LV end-systolic pressure and volume (LVESP and LVESV), LV end-diastolic pressure and volume (LVEDP and LVEDV), the maximum (dP/dtmax) rate of LV pressure change, time constant of LV pressure decay [τ; according to the Glantz method], EF and stroke work (SW) were computed and calculated using a special P-V analysis program (PVAN, Millar Instruments).

Article Title: Therapeutic effects on the development of heart failure with preserved ejection fraction by the sodium-glucose cotransporter 2 inhibitor dapagliflozin in type 2 diabetes
Article Snippet: A commercially available programme (PVAN, Millar Instruments, Houston, USA) was used to calculate mean arterial pressure (MAP), ejection fraction (EF), cardiac output (CO), the maximal slope of systolic pressure increment (dP/dt max ), and diastolic pressure decrement (dP/dt min ), and time constant of LV pressure decay (Tau w ).

Article Title: Targeted P2X 7 R shRNA delivery attenuates sympathetic nerve sprouting and ameliorates cardiac dysfunction in rats with myocardial infarction.
Article Snippet: Background: Inflammation-dominated sympathetic sprouting adjacent to the necrotic region following myocardial infarction (MI) has been implicated in the etiology of arrhythmias resulting in sudden cardiac death; however, the mechanisms responsible remain to be elucidated.. Although P2X7R is a key immune mediator, its role has yet to be explored.. Objective: We investigated whether P2X7R regulates NF-κB and affects cardiac sympathetic reinnervation in rats undergoing MI.

Article Title: Cardiac effects of acute exhaustive exercise in a rat model.
Article Snippet: Briefly, with the use of a special P-V analysis program (PVAN, Millar Instruments), heart rate (HR), LV end-systolic pressure (LVESP), LV end-diastolic pressure (LVEDP), the maximal slope of LV systolic pressure increment (dP/dtmax) and diastolic pressure decrement (dP/dtmin), time constant of LV pressure decay [τ; according to the Weiss method and Glantz method], LV end-systolic volume (LVESV), LV end-diastolic volume (LVEDV), stroke volume (SV), cardiac output (CO), ejection fraction (EF) and stroke work (SW) were computed and calculated.

Article Title: Inhibition of Notch signaling pathway attenuates sympathetic hyperinnervation together with the augmentation of M2 macrophages in rats post-myocardial infarction.
Article Snippet: A 2-Fr microtip P-V catheter (SPR-869; Millar Instruments, Houston, TX) was inserted into the right carotid artery and advanced into the ascending aorta to measure left ventricular (LV) systolic and diastolic pressure as the mean of measurements of five consecutive pressure cycles with the use of a special P-V analysis program (PVAN, Millar Instruments) (18, 36).

Article Title: A comparison of passive hindlimb cycling and active upper-limb exercise provides new insights into systolic dysfunction after spinal cord injury.
Article Snippet: Using specialized PV analysis software (PVAN, 199 Millar Instruments) the following systolic indices were measured from the final 30s of baseline data; end-200 systolic pressure (Pes); the maximal rate of rise of the LV pressure waveform (dP/dtmax); stroke work 201 (SW; area inside the PV loop); CO; and SV.

Stripping:

Article Title: Olaparib protects cardiomyocytes against oxidative stress and improves graft contractility during the early phase after heart transplantation in rats
Article Snippet: With the use of a special pressure‐volume analysis programme (PVAN, Millar Instruments, Houston, TX, USA), heart rate, systolic and diastolic blood pressures, mean arterial pressure, LV end‐systolic pressure, LV end‐diastolic pressure, effective arterial elastance (Ea), maximal slope of systolic pressure increment (dP/dt max ) and diastolic pressure decrement (dP/dt min ), and time constant of the left ventricular pressure decay (Tau‐g; according to the Glantz method (Pacher et al., 2008 )) were calculated.

Article Title: Cinaciguat prevents the development of pathologic hypertrophy in a rat model of left ventricular pressure overload
Article Snippet: LV end-systolic pressure and volume (LVESP and LVESV), LV end-diastolic pressure and volume (LVEDP and LVEDV), the maximum (dP/dtmax) rate of LV pressure change, time constant of LV pressure decay [τ; according to the Glantz method], EF and stroke work (SW) were computed and calculated using a special P-V analysis program (PVAN, Millar Instruments).

Article Title: Therapeutic effects on the development of heart failure with preserved ejection fraction by the sodium-glucose cotransporter 2 inhibitor dapagliflozin in type 2 diabetes
Article Snippet: A commercially available programme (PVAN, Millar Instruments, Houston, USA) was used to calculate mean arterial pressure (MAP), ejection fraction (EF), cardiac output (CO), the maximal slope of systolic pressure increment (dP/dt max ), and diastolic pressure decrement (dP/dt min ), and time constant of LV pressure decay (Tau w ).

Article Title: Targeted P2X 7 R shRNA delivery attenuates sympathetic nerve sprouting and ameliorates cardiac dysfunction in rats with myocardial infarction.
Article Snippet: Background: Inflammation-dominated sympathetic sprouting adjacent to the necrotic region following myocardial infarction (MI) has been implicated in the etiology of arrhythmias resulting in sudden cardiac death; however, the mechanisms responsible remain to be elucidated.. Although P2X7R is a key immune mediator, its role has yet to be explored.. Objective: We investigated whether P2X7R regulates NF-κB and affects cardiac sympathetic reinnervation in rats undergoing MI.

Article Title: Cardiac effects of acute exhaustive exercise in a rat model.
Article Snippet: Briefly, with the use of a special P-V analysis program (PVAN, Millar Instruments), heart rate (HR), LV end-systolic pressure (LVESP), LV end-diastolic pressure (LVEDP), the maximal slope of LV systolic pressure increment (dP/dtmax) and diastolic pressure decrement (dP/dtmin), time constant of LV pressure decay [τ; according to the Weiss method and Glantz method], LV end-systolic volume (LVESV), LV end-diastolic volume (LVEDV), stroke volume (SV), cardiac output (CO), ejection fraction (EF) and stroke work (SW) were computed and calculated.

Article Title: Inhibition of Notch signaling pathway attenuates sympathetic hyperinnervation together with the augmentation of M2 macrophages in rats post-myocardial infarction.
Article Snippet: A 2-Fr microtip P-V catheter (SPR-869; Millar Instruments, Houston, TX) was inserted into the right carotid artery and advanced into the ascending aorta to measure left ventricular (LV) systolic and diastolic pressure as the mean of measurements of five consecutive pressure cycles with the use of a special P-V analysis program (PVAN, Millar Instruments) (18, 36).

Article Title: A comparison of passive hindlimb cycling and active upper-limb exercise provides new insights into systolic dysfunction after spinal cord injury.
Article Snippet: Using specialized PV analysis software (PVAN, 199 Millar Instruments) the following systolic indices were measured from the final 30s of baseline data; end-200 systolic pressure (Pes); the maximal rate of rise of the LV pressure waveform (dP/dtmax); stroke work 201 (SW; area inside the PV loop); CO; and SV.

Software:

Article Title: Olaparib protects cardiomyocytes against oxidative stress and improves graft contractility during the early phase after heart transplantation in rats
Article Snippet: With the use of a special pressure‐volume analysis programme (PVAN, Millar Instruments, Houston, TX, USA), heart rate, systolic and diastolic blood pressures, mean arterial pressure, LV end‐systolic pressure, LV end‐diastolic pressure, effective arterial elastance (Ea), maximal slope of systolic pressure increment (dP/dt max ) and diastolic pressure decrement (dP/dt min ), and time constant of the left ventricular pressure decay (Tau‐g; according to the Glantz method (Pacher et al., 2008 )) were calculated.

Article Title: Cinaciguat prevents the development of pathologic hypertrophy in a rat model of left ventricular pressure overload
Article Snippet: LV end-systolic pressure and volume (LVESP and LVESV), LV end-diastolic pressure and volume (LVEDP and LVEDV), the maximum (dP/dtmax) rate of LV pressure change, time constant of LV pressure decay [τ; according to the Glantz method], EF and stroke work (SW) were computed and calculated using a special P-V analysis program (PVAN, Millar Instruments).

Article Title: Therapeutic effects on the development of heart failure with preserved ejection fraction by the sodium-glucose cotransporter 2 inhibitor dapagliflozin in type 2 diabetes
Article Snippet: A commercially available programme (PVAN, Millar Instruments, Houston, USA) was used to calculate mean arterial pressure (MAP), ejection fraction (EF), cardiac output (CO), the maximal slope of systolic pressure increment (dP/dt max ), and diastolic pressure decrement (dP/dt min ), and time constant of LV pressure decay (Tau w ).

Article Title: Targeted P2X 7 R shRNA delivery attenuates sympathetic nerve sprouting and ameliorates cardiac dysfunction in rats with myocardial infarction.
Article Snippet: Background: Inflammation-dominated sympathetic sprouting adjacent to the necrotic region following myocardial infarction (MI) has been implicated in the etiology of arrhythmias resulting in sudden cardiac death; however, the mechanisms responsible remain to be elucidated.. Although P2X7R is a key immune mediator, its role has yet to be explored.. Objective: We investigated whether P2X7R regulates NF-κB and affects cardiac sympathetic reinnervation in rats undergoing MI.

Article Title: Cardiac effects of acute exhaustive exercise in a rat model.
Article Snippet: Briefly, with the use of a special P-V analysis program (PVAN, Millar Instruments), heart rate (HR), LV end-systolic pressure (LVESP), LV end-diastolic pressure (LVEDP), the maximal slope of LV systolic pressure increment (dP/dtmax) and diastolic pressure decrement (dP/dtmin), time constant of LV pressure decay [τ; according to the Weiss method and Glantz method], LV end-systolic volume (LVESV), LV end-diastolic volume (LVEDV), stroke volume (SV), cardiac output (CO), ejection fraction (EF) and stroke work (SW) were computed and calculated.

Article Title: Inhibition of Notch signaling pathway attenuates sympathetic hyperinnervation together with the augmentation of M2 macrophages in rats post-myocardial infarction.
Article Snippet: A 2-Fr microtip P-V catheter (SPR-869; Millar Instruments, Houston, TX) was inserted into the right carotid artery and advanced into the ascending aorta to measure left ventricular (LV) systolic and diastolic pressure as the mean of measurements of five consecutive pressure cycles with the use of a special P-V analysis program (PVAN, Millar Instruments) (18, 36).

Article Title: A comparison of passive hindlimb cycling and active upper-limb exercise provides new insights into systolic dysfunction after spinal cord injury.
Article Snippet: Using specialized PV analysis software (PVAN, 199 Millar Instruments) the following systolic indices were measured from the final 30s of baseline data; end-200 systolic pressure (Pes); the maximal rate of rise of the LV pressure waveform (dP/dtmax); stroke work 201 (SW; area inside the PV loop); CO; and SV.

Irradiation:

Article Title: Olaparib protects cardiomyocytes against oxidative stress and improves graft contractility during the early phase after heart transplantation in rats
Article Snippet: With the use of a special pressure‐volume analysis programme (PVAN, Millar Instruments, Houston, TX, USA), heart rate, systolic and diastolic blood pressures, mean arterial pressure, LV end‐systolic pressure, LV end‐diastolic pressure, effective arterial elastance (Ea), maximal slope of systolic pressure increment (dP/dt max ) and diastolic pressure decrement (dP/dt min ), and time constant of the left ventricular pressure decay (Tau‐g; according to the Glantz method (Pacher et al., 2008 )) were calculated.

Article Title: Cinaciguat prevents the development of pathologic hypertrophy in a rat model of left ventricular pressure overload
Article Snippet: LV end-systolic pressure and volume (LVESP and LVESV), LV end-diastolic pressure and volume (LVEDP and LVEDV), the maximum (dP/dtmax) rate of LV pressure change, time constant of LV pressure decay [τ; according to the Glantz method], EF and stroke work (SW) were computed and calculated using a special P-V analysis program (PVAN, Millar Instruments).

Article Title: Therapeutic effects on the development of heart failure with preserved ejection fraction by the sodium-glucose cotransporter 2 inhibitor dapagliflozin in type 2 diabetes
Article Snippet: A commercially available programme (PVAN, Millar Instruments, Houston, USA) was used to calculate mean arterial pressure (MAP), ejection fraction (EF), cardiac output (CO), the maximal slope of systolic pressure increment (dP/dt max ), and diastolic pressure decrement (dP/dt min ), and time constant of LV pressure decay (Tau w ).

Article Title: Targeted P2X 7 R shRNA delivery attenuates sympathetic nerve sprouting and ameliorates cardiac dysfunction in rats with myocardial infarction.
Article Snippet: Background: Inflammation-dominated sympathetic sprouting adjacent to the necrotic region following myocardial infarction (MI) has been implicated in the etiology of arrhythmias resulting in sudden cardiac death; however, the mechanisms responsible remain to be elucidated.. Although P2X7R is a key immune mediator, its role has yet to be explored.. Objective: We investigated whether P2X7R regulates NF-κB and affects cardiac sympathetic reinnervation in rats undergoing MI.

Article Title: Cardiac effects of acute exhaustive exercise in a rat model.
Article Snippet: Briefly, with the use of a special P-V analysis program (PVAN, Millar Instruments), heart rate (HR), LV end-systolic pressure (LVESP), LV end-diastolic pressure (LVEDP), the maximal slope of LV systolic pressure increment (dP/dtmax) and diastolic pressure decrement (dP/dtmin), time constant of LV pressure decay [τ; according to the Weiss method and Glantz method], LV end-systolic volume (LVESV), LV end-diastolic volume (LVEDV), stroke volume (SV), cardiac output (CO), ejection fraction (EF) and stroke work (SW) were computed and calculated.

Article Title: Inhibition of Notch signaling pathway attenuates sympathetic hyperinnervation together with the augmentation of M2 macrophages in rats post-myocardial infarction.
Article Snippet: A 2-Fr microtip P-V catheter (SPR-869; Millar Instruments, Houston, TX) was inserted into the right carotid artery and advanced into the ascending aorta to measure left ventricular (LV) systolic and diastolic pressure as the mean of measurements of five consecutive pressure cycles with the use of a special P-V analysis program (PVAN, Millar Instruments) (18, 36).

Article Title: A comparison of passive hindlimb cycling and active upper-limb exercise provides new insights into systolic dysfunction after spinal cord injury.
Article Snippet: Using specialized PV analysis software (PVAN, 199 Millar Instruments) the following systolic indices were measured from the final 30s of baseline data; end-200 systolic pressure (Pes); the maximal rate of rise of the LV pressure waveform (dP/dtmax); stroke work 201 (SW; area inside the PV loop); CO; and SV.



Similar Products

90
Millar Inc pvan ultra 1.1 data analysis software
Pvan Ultra 1.1 Data Analysis Software, supplied by Millar Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/pvan/pvan+ultra+1+1+data+analysis+software/pm40358169-117-4-10
Average 90 stars, based on 1 article reviews
pvan ultra 1.1 data analysis software - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
ADInstruments pvan 2.3 software
Pvan 2.3 Software, supplied by ADInstruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/pvan/pvan+software/pm38827476-88-40-42
Average 90 stars, based on 1 article reviews
pvan 2.3 software - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Millar Inc pvan software
Pvan Software, supplied by Millar Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/pvan/pvan+software/pm38950776-131-11-13
Average 90 stars, based on 1 article reviews
pvan software - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Millar Inc p-v analysis program pvan
P V Analysis Program Pvan, supplied by Millar Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/pvan/p+v+analysis+program+pvan/pm38788603-108-2-6
Average 90 stars, based on 1 article reviews
p-v analysis program pvan - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Millar Inc pvan 3.4
Pvan 3.4, supplied by Millar Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/pvan/pvan+3+5+software/pmc10886269-154-14-13
Average 90 stars, based on 1 article reviews
pvan 3.4 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Millar Inc pvan (v3.6)
Pvan (V3.6), supplied by Millar Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/pvan/pvan+v3+6/pm37985159-71-12-14
Average 90 stars, based on 1 article reviews
pvan (v3.6) - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results